Das S.; Karanki S.B.2025-02-1720212http://dx.doi.org/10.1109/NPEC52100.2021.9672497https://idr.iitbbs.ac.in/handle/2008/3587In this paper, a three phase single-stage differential boost inverter (DBI) topology has been analyzed to quantify the performance of the proposed controller. DBI offers certain advantages like small structure, reduced power switches, and good buck boost ability. A comprehensive double loop controller has been proposed to integrate the 3-f DBI to the grid. Perturb Observe (PO) maximum power point tracking (MPPT) algorithm has been implemented to get the DC link voltage reference followed by a synchronous rotating reference frame based Proportional Integral (PI) controller. A cascaded control loop for voltage tracking performance and inductor current control of 3-f DBI have been implemented. The topology with the proposed control algorithm has been verified both in MATLAB Simulink and experimentally by developing a hardware prototype. � 2021 IEEE.enDifferential Boost Inverter; Maximum Power Point Tracking; Proportional Integral; Synchronous Rotating FrameA Three-phase Single Stage Differential Boost Inverter for PV IntegrationConference paper