Automated ECG noise detection and classification system for unsupervised healthcare monitoring

dc.contributor.authorSatija U.en_US
dc.contributor.authorRamkumar B.en_US
dc.contributor.authorManikandan M.S.en_US
dc.date.accessioned2025-02-17T06:54:38Z
dc.date.issued2018
dc.description.abstractObjective: Automatic detection and classification of noises can play a vital role in the development of robust unsupervised electrocardiogram (ECG) analysis systems. This paper proposes a novel unified framework for automatic detection, localization, and classification of single and combined ECG noises. Methods : The proposed framework consists of the modified ensemble empirical mode decomposition (CEEMD), the short-term temporal feature extraction, and the decision-rule-based noise detection and classification. In the proposed framework, ECG signals are first decomposed using the modified CEEMD algorithm for discriminating the ECG components from the noises and artifacts. Then, the short-term temporal features such as maximum absolute amplitude, number of zerocrossings, and local maximum peak amplitude of the autocorelation function are computed from the extracted high-frequency and low-frequency signals. Finally, a decision rule-based algorithm is presented for detecting the presence of noises and classifying the processed ECG signals into six signal groups: noise-free ECG, ECG+BW, ECG+MA, ECG+PLI, ECG+BW+PLI, and ECG+BW+MA. Results: The proposed framework is rigorously evaluated on five benchmark ECG databases and the real-time ECG signals. The proposed framework achieves an average sensitivity of 99.12%, specificity of 98.56%, and overall accuracy of 98.90% in detecting the presence of noises. Classification results show that the framework achieves an average sensitivity, positive predictivity, and classification accuracy of 98.93%, 98.39%, and 97.38%, respectively. Conclusion: The proposed framework not only achieves better noise detection and classification rates than the current state-of-the-art methods but also accurately localizes short bursts of noises with low endpoint delineation errors. Significance: Extensive studies on benchmark databases demonstrate that the proposed framework is more suitable for reducing false alarm rates and selecting appropriate noise-specific denoising techniques in automated ECG analysis applications. � 2013 IEEE.en_US
dc.identifier.citation13en_US
dc.identifier.urihttp://dx.doi.org/10.1109/JBHI.2017.2686436
dc.identifier.urihttps://idr.iitbbs.ac.in/handle/2008/1872
dc.language.isoenen_US
dc.subjectBaseline wanderen_US
dc.subjectECG denoisingen_US
dc.subjectECG noise detection and classificationen_US
dc.subjectECG signal quality assessmenten_US
dc.subjectmuscle artifactsen_US
dc.titleAutomated ECG noise detection and classification system for unsupervised healthcare monitoringen_US
dc.typeArticleen_US