IDR Logo

Please use this identifier to cite or link to this item: http://idr.iitbbs.ac.in/jspui/handle/2008/986
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAdamczyk K.en_US
dc.contributor.authorAihara H.en_US
dc.contributor.authorAngelini C.en_US
dc.contributor.authorAziz T.en_US
dc.contributor.authorBabu V.en_US
dc.contributor.authorBacher S.en_US
dc.contributor.authorBahinipati S.en_US
dc.contributor.authorBarberio E.en_US
dc.contributor.authorBaroncelli T.en_US
dc.contributor.authorBasith A.K.en_US
dc.contributor.authorBatignani G.en_US
dc.contributor.authorBauer A.en_US
dc.contributor.authorBehera P.K.en_US
dc.contributor.authorBergauer T.en_US
dc.contributor.authorBettarini S.en_US
dc.contributor.authorBhuyan B.en_US
dc.contributor.authorBilka T.en_US
dc.contributor.authorBosi F.en_US
dc.contributor.authorBosisio L.en_US
dc.contributor.authorBozek A.en_US
dc.contributor.authorBuchsteiner F.en_US
dc.contributor.authorCasarosa G.en_US
dc.contributor.authorCeccanti M.en_US
dc.contributor.author?ervenkov D.en_US
dc.contributor.authorChendvankar S.R.en_US
dc.contributor.authorDash N.en_US
dc.contributor.authorDivekar S.T.en_US
dc.contributor.authorDole�al Z.en_US
dc.contributor.authorDutta D.en_US
dc.contributor.authorForti F.en_US
dc.contributor.authorFriedl M.en_US
dc.contributor.authorHara K.en_US
dc.contributor.authorHiguchi T.en_US
dc.contributor.authorHoriguchi T.en_US
dc.contributor.authorIrmler C.en_US
dc.contributor.authorIshikawa A.en_US
dc.contributor.authorJeon H.B.en_US
dc.contributor.authorJoo C.en_US
dc.contributor.authorKandra J.en_US
dc.contributor.authorKang K.H.en_US
dc.contributor.authorKato E.en_US
dc.contributor.authorKawasaki T.en_US
dc.contributor.authorKody� P.en_US
dc.contributor.authorKohriki T.en_US
dc.contributor.authorKoike S.en_US
dc.contributor.authorKolwalkar M.M.en_US
dc.contributor.authorKvasni?ka P.en_US
dc.contributor.authorLanceri L.en_US
dc.contributor.authorLettenbicher J.en_US
dc.contributor.authorMammini P.en_US
dc.contributor.authorMayekar S.N.en_US
dc.contributor.authorMohanty G.B.en_US
dc.contributor.authorMohanty S.en_US
dc.contributor.authorMorii T.en_US
dc.contributor.authorNakamura K.R.en_US
dc.contributor.authorNatkaniec Z.en_US
dc.contributor.authorNegishi K.en_US
dc.contributor.authorNisar N.K.en_US
dc.contributor.authorOnuki Y.en_US
dc.contributor.authorOstrowicz W.en_US
dc.contributor.authorPaladino A.en_US
dc.contributor.authorPaoloni E.en_US
dc.contributor.authorPark H.en_US
dc.contributor.authorPilo F.en_US
dc.contributor.authorProfeti A.en_US
dc.contributor.authorRashevskaya I.en_US
dc.contributor.authorRao K.K.en_US
dc.contributor.authorRizzo G.en_US
dc.contributor.authorRozanska M.en_US
dc.contributor.authorSandilya S.en_US
dc.contributor.authorSasaki J.en_US
dc.contributor.authorSato N.en_US
dc.contributor.authorSchultschik S.en_US
dc.contributor.authorSchwanda C.en_US
dc.contributor.authorSeino Y.en_US
dc.contributor.authorShimizu N.en_US
dc.contributor.authorStypula J.en_US
dc.contributor.authorTanaka S.en_US
dc.contributor.authorTanida K.en_US
dc.contributor.authorTaylor G.N.en_US
dc.contributor.authorThalmeier R.en_US
dc.contributor.authorThomas R.en_US
dc.contributor.authorTsuboyama T.en_US
dc.contributor.authorUozumi S.en_US
dc.contributor.authorUrquijo P.en_US
dc.contributor.authorVitale L.en_US
dc.contributor.authorVolpi M.en_US
dc.contributor.authorWatanuki S.en_US
dc.contributor.authorWatson I.J.en_US
dc.contributor.authorWebb J.en_US
dc.contributor.authorWiechczynski J.en_US
dc.contributor.authorWilliams S.en_US
dc.contributor.authorW�rkner B.en_US
dc.contributor.authorYamamoto H.en_US
dc.contributor.authorYin H.en_US
dc.contributor.authorYoshinobu T.en_US
dc.date.accessioned2020-01-13T11:06:19Z-
dc.date.available2020-01-13T11:06:19Z-
dc.date.issued2016-
dc.identifier.citation2en_US
dc.identifier.urihttp://dx.doi.org/10.1016/j.nima.2015.09.007-
dc.identifier.urihttp://10.10.32.48:8080/jspui/handle/2008/986-
dc.description.abstractThe Belle-II VerteX Detector (VXD) has been designed to improve the performances with respect to Belle and to cope with an unprecedented luminosity of 8�1035cm-2s-1 achievable by the SuperKEKB. Special care is needed to monitor both the radiation dose accumulated throughout the life of the experiment and the instantaneous radiation rate, in order to be able to promptly react to sudden spikes for the purpose of protecting the detectors. A radiation monitoring and beam abort system based on single-crystal diamond sensors is now under an active development for the VXD. The sensors will be placed in several key positions in the vicinity of the interaction region. The severe space limitations require a challenging remote readout of the sensors. � 2015 Elsevier B.V.en_US
dc.language.isoenen_US
dc.subjectBeam radiation monitoringen_US
dc.subjectCVD diamond sensorsen_US
dc.subjectDiamond radiation detectorsen_US
dc.subjectRadiation hardnessen_US
dc.titleBelle-II VXD radiation monitoring and beam abort with sCVD diamond sensorsen_US
dc.typeArticleen_US
Appears in Collections:Research Publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.